Generator Maintenance

- Oct 23, 2017 -

Generator maintenance

All the diesel generating units in the use of a period of time after the maintenance should be carried out; because it can not only timely elimination of the existing generating unit of the hidden dangers, but also to ensure that the generator is often in good working condition, extend the life of diesel generators The What should we pay attention to in the maintenance of the diesel engine?

Shangpu power generation unit maintenance can be divided into: daily maintenance, month maintenance, half year maintenance and maintenance. Diesel generator sets maintenance requirements are based on daily use to set. The basic requirements for maintenance of Shangchai generating units are as follows:

1, the generator water, electricity, oil, gas and other comprehensive inspection to confirm whether the unit is normal;

2, the first run 50 hours to check the oil and water separator within the water, the replacement of oil and oil filter;

3, every six months or one year to replace the air filter, diesel filter, oil, oil filter, water filter, oil and water separator filter and other supplies;

4, every six months or a year to add battery battery fluid;

5, every six months or a year to check the radiator is blocked, whether the need for cleaning;

6, check into the exhaust pipe and cylinder gasket seal;

7, check the supercharger oil into the oil should be no leakage;

8, check the degree of tension of the transmission belt;

9, cleaning the turbocharger rotor carbon deposition, check the bearing, impeller wear, if necessary, should be modified.

 The main purpose: diesel generating units in hospitals, hotels, hotels, real estate and other industries.

First, bring their own power. Some electrical units do not have electricity supply, such as far from the mainland islands, remote pastoral areas, rural areas, desert plateau camps, workstations, radar stations, etc., need to configure their own power supply. The so-called self-powered, that is, spontaneous power supply, power generation is not too much in the case of diesel generators often become the preferred power supply.

 Second, the backup power supply. Standby power supply, also known as emergency power supply, the main purpose is that although some of the electricity units have been more reliable and reliable power supply, but in order to prevent accidents, such as the emergence of a circuit failure or temporary power failure and the like, Power generation use. It can be seen that the backup power supply is actually a kind of self-contained power supply, but it is not used as a main power source, but only in emergency situations as a means of relief.